1. Product Overview |
|
||||
|
1.1Name |
High and low temperature test chamber |
|
|||
|
1.2Model |
LJGDP-150G |
|
|||
|
1.3Scope of application |
It is suitable for determining the adaptability of components, equipment or other products to use, transport and storage under the combined conditions of high and low temperature and temperature cycle changes. and equipment for evaluating use in high or low temperature environments. Widely used in military, aerospace, electronics, automotive, new energy, testing and other industries. |
|
|||
|
1.4meet the standard |
GB/T2423.1-2001TestALow Temperature Test Method GB/T2423.2-2001TestAHigh Temperature Test Method GB/T11158-2008Technical conditions for high temperature test chamber GB/T11158-2008 Technical conditions for low temperature test chamber GB/T2423.2-2001TestBHigh Temperature Test Method GJB150.4-2009 Low temperature test GJB150.3-2009 High temperature test GB/T5170.2-2008Temperature test equipment Gb/t gb/t 2423.22-2008TestNb: Temperature change test Gb/t gb/t 2423.22-2008TestNbAlternating damp heat test |
|
|||
|
2. Product use conditions and restrictions |
|
||||
|
2.1 site requirements
|
|
|
|||
|
|
Appropriate maintenance space around the equipment (as shown above) A:≥60cm B:≥60cm C:≥ 100cm D:≥60cm |
|
|||
|
|
|
|
|||
|
2.2 environmental requirements |
Temperature |
5~40 ℃ (5~35 ℃ to ensure the best performance) |
|
||
|
|
Humidity |
≤ 90% RH |
|
||
|
|
Air pressure |
86~106kpa |
|
||
|
2.3 User Power |
Installed power |
4.5KW |
|
||
|
|
Grounding Requirements |
|
|
||
|
|
Stability |
|
|
||
|
|
The user needs to configure the air or power switch with corresponding capacity for the equipment at the installation site, and the switch must be independent and dedicated for the equipment. |
|
|||
|
3. Product specifications |
|
||||
|
3.1 internal volume |
150L |
|
|||
|
3.2 internal dimensions |
WDH :500x500x600(mm) |
|
|||
|
3.3 dimensions |
WDH :750*1550*1700(mm) |
|
|||
|
4. Product technical parameters |
|
||||
|
Test environmental conditions |
Ambient temperature 5~35 ℃, relative humidity ≤ 85% RH test chamber without load (unless otherwise specified) |
|
|||
|
Test Method |
GB/T5170.2-2008-Temperature test equipment |
|
|||
|
4.1 temperature range |
-60 ℃ ~ 150 ℃ |
Remarks:
At the air outlet of the unit.
|
|
||
|
4.2 temperature uniformity |
≤ ± 2 ℃ |
|
|
||
|
4.3 temperature fluctuation |
≤ ± 0.3 ℃ |
|
|
||
|
4.4 temperature deviation |
≤ ± 2 ℃ |
|
|
||
|
4.5 heating rate |
≥3℃/min |
|
|
||
|
4.6 cooling speed |
≥1℃/min |
|
|
||
|
5. Product System Configuration |
|
||||
|
System Overview |
The main system consists of structure, refrigeration, heating and control. |
|
|||
|
5.1 structure and material |
|
|
|
||
|
5.1.1 Box structure |
Integral split type, environmental chamber and refrigeration unit, control panel on the door. |
|
|||
|
5.1.2 Material composition |
|
|
|||
|
|
|
|
|||
|
5.1.3 Box structure |
Outer wall material: high quality steel plate, surface spray treatment; |
|
|||
|
|
Appearance color: box for the lijia standard color; |
|
|||
|
|
Inner wall material: SUS304 stainless steel plate; |
|
|||
|
|
Thermal insulation material: composite thermal insulation material (glass woolpolyurethane foam board); All openings have effective sealing methods; such as wool felt, Soft silicone plug , Silicone seal; |
|
|||
|
5.1.4 Adjustment channel |
Fan, heater, evaporator, temperature sensor. |
||||
|
5.1.5 Internal airflow regulation Section |
Through the action of a high-power centrifugal fan, forced air circulation can achieve good temperature uniformity. |
||||
|
5.1.7 Control operation boundary Face |
Controller touch screen,USB interface, main power switch, over-temperature protection setting device, network interface, communication interface. |
||||
|
5.2 refrigeration system |
|||||
|
5.2.1 Refrigeration mode |
Mechanical compressionDoubleStage refrigeration |
||||
|
5.2.2 Cooling mode |
air-cooled |
||||
|
5.2.3 Refrigeration compressor |
Adopt French Taikang fully enclosed compressor, |
||||
|
5.2.4 Control mode |
With a cold end PID The regulation technology enables control to be achieved through the precise output of the compressor cooling capacity.The effect of temperature, cooling and maintaining the temperature below room temperature does not require the participation of a heater, the complete zone.Unlike the cold and heat balance temperature control method, that is, heating without cooling, cooling without heating, energy saving More than 40%.
|
||||
|
5.2.5 Refrigerant |
R404a |
||||
|
5.2.6 Condenser |
air-cooled condenser |
||||
|
5.2.7 Evaporator |
finned heat exchanger |
||||
|
5.2.8 Throttling device |
Capillary |
||||
|
5.2.9 Refrigeration system allocation |
⚫ |
Refrigeration compressor: France Taikang |
|||
|
Piece |
⚫ |
Pressure controller : Danfoss, Denmark DANFOSS |
|||
|
|
|
||||
|
5.3 heating system |
|||||
|
5.3.1 Heating mode |
Electric heater. Non-contact solid state relay control. The heater is evenly distributed behind the evaporator. In the air duct. |
||||
|
5.4 control system |
|||||
|
5.4.1 Controller |
7 inch 1024X768 dot matrix TFT color LCD monitor |
||||
|
5.4.2 Operation mode |
Procedure mode and fixed value mode |
||||
|
5.4.3 Setting Method |
Chinese menu, touch screen input |
||||
|
5.4.4 Program capacity |
200 group program, each group consists of 200 segments, the maximum 4000 segments. |
||||
|
5.4.5 Setting range |
Adjusted according to the temperature operating range of the device(Upper limit 5 ℃, lower limit -5 ℃) |
||||
|
5.4.6 Display resolution |
Temperature 0.1 ℃, time 1s, |
||||
|
5.4.7 Input |
Class A high precision armored platinum resistance; |
||||
|
5.4.8 Communication function |
Built-in Ethernet interface and wirelessWiFi can be upgraded to connect multiple computers to monitor and transfer files on the server side, or connect multiple mobile phones to monitor wirelessly through the network.. |
||||
|
5.4.9 Control mode |
Intelligent hot and cold PID |
||||
|
5.4.10USB Function |
Matching USB interface |
||||
|
5.4.11 Accessory Function |
|
||||
|
|
|
||||
|
5.4.12 Other configurations Power cable |
Five-wire (four-core cableProtective grounding wire) 1 cable (5 m long) |
||||
|
5.4.14 Control System Accessories |
|
||||
|
5.5 safety protection device |
|||||
|
5.5.1 Studio |
|
||||
|
5.5.2 Refrigeration system |
|
||||
|
5.5.3 Power supply system |
|
||||
|
5.5.4 Other |
|
||||
Online Inquiry