Rapid temperature change test chamber LJTKP-1000S-B20
Classification:
Standard temperature and humidity environmental test chamber
Key words:
Inquiry
Product Description
I. Design and Applicable Standards
GB/T2423.1-2001 Test A: Low Temperature Test Method
GB/T2423.2-2001 Test B: High Temperature Test Method
GB/T11158-2008-Specification for High Temperature Test Chamber
GB/T10589-2008 Technical Conditions for Low Temperature Test Chamber
GB/T 2423.22-2008 Tests Nb: Temperature Change Test
GB/T 2423.4-2008 test Db: damp heat test;
GB/T2423.3-2008 Constant damp heat test
GJB200.3-2009 high temperature test
GJB200.4-2009 low temperature test
Test Standard Requirements for Damp Heat Test of GJB200.9-2009
GB/T5170.2-2008 Temperature Test Equipment
II. Technical Parameters of Products
|
Product Name |
Rapid temperature change test chamber |
|||||||
|
Model |
LJTKP-1000S-B20 |
|||||||
|
Specimen Limits |
This test equipment prohibits the test of flammable, explosive and volatile substances; the test of storing corrosive substances, the test of storing organisms, and the test and storage of strong electromagnetic emission source samples. |
|||||||
|
Volume, weight and dimensions |
||||||||
|
Nominal internal volume |
1000L |
|||||||
|
Effective size of inner box |
1000mm × 1000mm × 1000mm (W×D×H) |
|||||||
|
Effective dimensions of outer box |
1500mm × 2350mm ×2300MM (w×d×h) |
|||||||
|
performance index |
||||||||
|
Functional Requirements |
1.(air) indoor space cooling, heating; 2. According to the set temperature parameters, make the indoor space meet the requirements of the set temperature parameters; 3. Each function can be operated independently; |
|||||||
|
Environmental requirements
|
Input voltage: three-phase AC 380V±10%; Power frequency:50Hz±2%;Total power:70KW Grounding resistance of protective earth wire: <4Ω; Working environment temperature:-5 ℃ ~ 45 ℃; Working environment humidity:≤ 90% RH, non-condensing; Working environment air pressure: 86~106kpa; Operating noise:≤ 70dB; No abrasive dust, corrosive gas, no strong electromagnetic interference signal Cooling method:WaterCold. |
|||||||
|
Studio Requirements |
*Temperature range: |
-70℃ ~180℃ (180 ℃ continuous operation time is not less than 2 hours) |
||||||
|
Temperature fluctuation |
≤ ± 0.5 ℃ |
|||||||
|
Temperature deviation |
≤ ± 2 ℃ |
|||||||
|
heating rate |
≥ 20 ℃/min(-55 ℃ → +85 ℃ average in the whole process, with load of 30kg aluminum ingot, air outlet at measuring point); ≥ 15 ℃/min(-40 ℃ → 80 ℃ linear, with load of 30kg aluminum ingot, air outlet at measuring point); |
|||||||
|
cooling rate |
≥ 20 ℃/min( 85 ℃ →-55 ℃ average in the whole process, with load of 30kg aluminum ingot, air outlet at measuring point); ≥ 15 ℃/min( 80 ℃ →-40 ℃ linear, with load of 30kg aluminum ingot, air outlet at measuring point); |
|||||||
|
temperature acquisition |
Installation in the box4 thermocouples monitor the temperature at 4 points in the boxor monitor product surface temperature, through the man-machine interface display, there can be curve records andUSB readout. |
|||||||
|
Noise |
Less75dB(Distance1mmeasured value) |
|||||||
|
4.1 structural features: |
||||||||
|
Box |
Box material |
Inner wall:SUS304 stainless steel plate; ExternalCold-rolled steel plate is sprayed with plastic; The surface is electrostatically sprayed after pickling and phosphating treatment.. |
||||||
|
Insulation layer |
The thickness of the insulation layer of the whole inner box body is up 150MM, using fire-resistant high-strength PU polyurethane foam insulation, materials (more than the general PU heat, fire-resistant effect),High strength, non-absorbent Thermal insulation coefficient: Less than 0.0212kcal/m · hr insulation layer fireproof with fireproof layer design, insulation layer is made of high temperature resistant rock wool plus fireproof gypsum board layer. It can ensure that the thermal insulation material will not melt and burn after fire in the test process of the box.; |
|||||||
|
Sample Rack |
Material is stainless steel,Standard2 plies,Bulkhead bearing capacity≥ 50kg, height adjustable; |
|||||||
|
Insulating Laminate |
Matching can cover the size of the placing rack PTFE pad2, with a margin of 80mm, evenly arranged in the middle with a circular hole with a diameter of 45mm; |
|||||||
|
Large door handle |
Adopt imported strong pressure steel lock, can be locked, key*2. |
|||||||
|
Viewing window |
Viewing window is adoptedManyLayer hollow tempered glass, size:W440 ×H600mm, the inner side is equipped with automatic heating defrosting and defogging functions, and is equipped with lighting lamps. |
|||||||
|
Lead test hole |
Box leftright twoSideEachConfigure aφ100mm test hole, and attach the corresponding thermal insulation fittings and special sealing soft plug. |
|||||||
|
Illumination lamp |
The test box is equipped with a long-life controlled observation light source, which is controlled from the instrument control system,LED explosion-proof lamp 1one; |
|||||||
|
Adjusting channel |
Fan, heater, evaporator, temperature sensor. |
|||||||
|
Internal airflow regulation |
Through the action of a high-power centrifugal fan, forced air circulation can achieve good temperature uniformity. |
|||||||
|
Circulating fan |
Adopt high-temperature resistant, long-axis motor, the motor is installed in the outdoor space, the shaft extends to the room, and a mixing wind wheel is installed at the end of the shaft; Special heat insulation measures and heat dissipation system improve the safety of the motor. |
|||||||
|
Control operation interface |
Controller touch screen,USB interface, main power switch, over-temperature protection setting device, network interface, communication interface. |
|||||||
|
Emergency stop switch |
Emergency stop switch with semicircular mushroom head protective cover. Emergency stop to cut off all the energy, when the emergency stop button is released, the safety control circuit of the device to prohibit automatic reset (only manual reset). |
|||||||
|
Equipment operation indicator |
A three-color audible and visual alarm is installed on the top of the electrical control cabinet, which can display the three states of equipment operation, stop and alarm. Yellow represents standby, green represents operation, and red represents fault |
|||||||
|
Caster |
Equipment configuration Universal Forma Wheel4, easy to move. |
|||||||
|
Dry air purging system |
Equipped with purging device to prevent the sudden rise and drop of temperature from causing condensation and frost on the inner wall of the box. 1. Equipment form: no heat regeneration type 2.100% saturated compressed air for treatment medium 3. Treatment gas volume (Nm3/min) 1 4. Working pressure (Mpa (G)) 0.6-0.8 5. Design pressure (Mpa (G)) 1.0 6. Intake air temperature (℃) ≤ 35 7. Atmospheric dew point (℃)≤-60 8. Average air consumption 5-8% 9. Pressure loss (Mpa)≤ 0.015 10. Weight of desiccant (Kg/tower) 11. Standard working cycle (min) 4 12. Automatic control of control system 13. Maximum noise <80dB(A) 14. Air inlet/outlet size DN15 |
|||||||
|
4.2 test chamber safety device |
||||||||
|
Control Panel |
Adopt7 inch large screen LCD touch programmable controller; |
|||||||
|
Fault indicator lamp, adjustable over-temperature protection, main power switch,USB interface; |
||||||||
|
Temperature and humidity sensor |
United StatesOMEGA -100℃-250℃; |
|||||||
|
Set time capacity |
0 H 1 M ~ 99999 H |
|||||||
|
Booking time |
Appointment time setting function |
|||||||
|
Screen display |
Color real-time curve display |
|||||||
|
Design of Software Device for Fault Medical Records |
Machine maintenance, timely control and storage/Record/Analysis/e-mail |
|||||||
|
Temperature protection up and down line |
Automatic setting of high and low temperature protection up and down line (sound and light alarm device) |
|||||||
|
Protection device |
automatic monitoring safety protection system |
|||||||
|
Mode selection |
Fixed-point or programmable mode |
|||||||
|
4.3 protection function |
||||||||
|
electric leakage/surge prevention protection |
electric leakage/surge prevention protection |
|||||||
|
High and low temperature over-temperature protection |
High and low temperature over-temperature protection |
|||||||
|
Circulating fan protection |
Fan overcurrent and overheat protection |
|||||||
|
Test chamber door opening protection |
Equipment stops air supply after opening the door |
|||||||
|
Compressor protection |
Refrigerant pressure protection and overload protection, compressor oil leakage protection, compressor overheating protection, |
|||||||
|
Fault Abnormal Protection |
Fault cause indication and alarm output signal |
|||||||
|
Normal temperature protection |
After shutdown, the test piece of the machine & the test area will automatically drop to normal temperature protection |
|||||||
|
Machinery Room |
Refrigeration unit, air conditioning fan, cooling fan, pneumatic device |
|||||||
|
Power distribution control cabinet |
Total power leakage circuit breaker, controller, distribution board |
|||||||
|
Power line hole and drain hole |
Located on the back of the box; Note: It can be determined according to the installation site of the customer's equipment; |
|||||||
|
Mode of transport |
Motor transport |
|||||||
|
4.4 electrical control system |
||||||||
|
Operation mode |
Procedure mode and fixed value mode;
|
|||||||
|
Setting method |
Chinese and English menu, touch screen input; |
|||||||
|
Setting range |
Temperature: Adjust according to the temperature working range of the equipment(upper limit 5 ℃, lower limit -5 ℃); |
|||||||
|
Program Capacity |
Max.200 group program, each group consists of 200 segments, the maximum 4000 segments. |
|||||||
|
Display Resolution |
Temperature 0.01 ℃, |
|||||||
|
Sensor |
Class A high precision armored platinum resistance; |
|||||||
|
Fan |
Low noise, multi-wing, high temperature centrifugal fan; |
|||||||
|
control instrument |
7-inch touch screen PLC control system ≥:24-bit high-precision acquisition: 6-channel switchable thermal resistance, thermocouple, 0-5V and 3-channel 4-20ma, high-precision 0.01; 3-channel PID independent control Touch screen resolution≥ 1920*1080, main frequency 4 cores, 1GHZ; Serial port: 232/485/485/network port; Specific 4G IOU card data transmission function. |
|||||||
|
Display contents |
It can directly input, display and control the temperature, and is equipped with the special software of our company's test box. The control system adopts man-machine dialogue mode; it has automatic, intelligent and humanized design. The control system can display and set test parameters, program curves, working time, heater, refrigeration unit, fan working status. At the same time, the test program runs automatically and.PID parameter self-tuning function; can automatically combine the heating system, refrigeration system, circulating fan, over-temperature alarm and other subsystems to work, so as to ensure the high control quality of the entire temperature control system, the main implementation of electrical SCHNEIDER brand |
|||||||
|
Communication function |
① equipped with curve generation software, software lifetime free update; ② Network monitoring; ③ The test curve can be backed up by U disk; ④ It can record continuously in real time, has the function of remote receiving data from remote IOT card, and open communication protocol. National Computer Software Copyright Registration Certificate No. No. 0698434 *EquippedThe LAN interface is connected to the computer; it can realize the intercommunication with the charging and discharging cabinet and the control of the software on the computer. * Recording function:The memory of the controller can automatically record test curves and data, equipment status, alarm status, etc., and can be downloaded through the Internet. * With RS-485 and Ethernet remote communication interface,Open communication protocol to realize communication and control with charging and discharging cabinet equipment |
|||||||
|
SubsidiaryFunction: |
Upper and lower limit temperature protection function (sound and light alarm device), the control system also has self-detection, self-diagnosis function, automatic fault display, alarm; automatic operation and stop timing function; self-diagnosis function, with a variety of power-off recovery mode, after the completion of the test with automatic shutdown and sound and light prompt |
|||||||
|
PID group control
|
PID control, LCD display, color touch screen operation,The controller has fault self-diagnosis capability,RS232 communication interface, equipped with software to support PC monitoring; |
|||||||
|
Data recording method |
Equipped with memory to save the set and sampled values of the device; data can be downloaded U disk, U disk can also be stored directly. |
|||||||
|
Software |
SoftwareV1.0. The curves and data recorded by the machine can be stored on the computer and used online. The stored data cannot be changed, and the data can be retrieved at any time. The data can be viewed in any office; National Computer Software Copyright Registration Certificate No. No. 0698434; |
|||||||
|
Schematic diagram of 4.5 system
|
||||||||
|
4.6 refrigeration system
|
||||||||
|
Compressor:
|
Original BITZER compressor unit refrigeration. This test chamber is realized by mechanical refrigeration based on a double-machine cascade refrigeration system. The refrigeration system is composed of a cascade compressor unit. In order to ensure the cooling rate of the test chamber and reach the lowest temperature, a German compressor is used to form a refrigeration cycle system. The high temperature part is composed of compressor, oil separator, water condenser, expansion valve, condensing evaporator, filter dryer, solenoid valve, etc.R404A; The low temperature part is composed of compressor, oil separator, expansion valve, evaporator, expansion vessel, filter dryer, solenoid valve, etc. The working fluid R23 is used to realize the cooling of the box; |
|||||||
|
Energy saving measures: |
With a cold end PID The regulation technology enables control to be achieved through the precise output of the compressor cooling capacity.The effect of temperature, cooling and maintaining the temperature below room temperature does not require the participation of a heater, the complete zone.Unlike the cold and heat balance temperature control method, that is, heating without cooling, cooling without heating, energy saving More than 40%.
|
|||||||
|
Condensation mode: |
water cooling refrigeration |
|||||||
|
Noise reduction measures are available in the refrigeration cabinet |
Adopt compressor integral vibration damping and spring vibration damping; The inner wall of the chassis is pasted with sound-absorbing cotton. |
|||||||
|
Evaporator: |
The coil of the evaporator, the heat transfer coefficient is greater20; |
|||||||
|
Refrigerant |
Non-Fluorine Environmentally Friendly Refrigerant (DuPont, USA)R404andR23; |
|||||||
|
Condenser |
It has the characteristics of good cooling effect and low indoor noise; |
|||||||
|
Refrigeration accessories |
Refrigeration compressor: France Taikang Pressure controller : Danfoss, Denmark DANFOSS Solenoid valve: American Parker Filter: Danfoss Denmark DANFOSS |
|||||||
|
4.7 electrical control system |
||||||||
|
Heater mode |
Imported closed nickel-chromium alloy electric heater; |
|||||||
|
Heating control mode |
BTHC balanced temperature control mode and PID; Non-contact equal periodic pulse width modulation, SSR (solid state relay); |
|||||||
|
4.8 duct system
|
The fan is used to circulate the air in the box. When the fan rotates at high speed, the air in the working room is sucked into the air duct, and blown out from the air duct after heating and cooling. The air exchanged with the test product temperature in the working room is then sucked into the air duct and circulated repeatedly to meet the temperature setting requirements; |
|||||||
|
4.9 water, electricity and gas requirements and installation |
||||||||
|
||||||||
|
5.0 measurement requirements: Party B shall measure the equipment and provide a certificate, and the measurement institution shall be Grade II or above.
|
||||||||
|
5.1Conditions of use |
||||||||
|
The following conditions are guaranteed by the user: |
||||||||
|
Environmental conditions |
The ambient temperature of the equipment should be maintained.5℃ ~3Within 5 ℃; Ambient humidity:20%~85%RH;Atmospheric pressure:86~101Q7; |
|||||||
|
Water quality requirements and others |
Party A is required to provide pressure Water source of 0.2~0.4 Mpa, drainage pipe with diameter above φ20 to water tower site; Compliance GB 50050-1995 Code for design of industrial circulating cooling water treatment; It is recommended to install an electrostatic (descaling/algae killing) water processor on the waterway; |
|||||||
|
Power supply condition and power supply
|
AC380V three-phase four-wire protective grounding;Power:95KW Allowable voltage fluctuation range:AC(380±38)V; Allowable fluctuation range of frequency: (50±0.5)HZ; TN-S mode power supply or TT mode power supply; Grounding resistance of protective earth wire is less4Ω; The user is required to configure the air or power switch with corresponding capacity for the equipment at the installation site, and the switch must be independently controlled for use of the equipment; |
|||||||
|
Requirements for storage environment |
When the ambient temperature is lowerAt 0 ℃, (the equipment is stopped for a long time), the water retained in the equipment should be drained clean to avoid the water in the pipeline from freezing and damaging the pipeline; |
|||||||