  • Battery combustion testing machine LJ-5880.jpg

Battery combustion testing machine LJ-5880

Classification:

New energy battery testing equipment

Key words:


Inquiry

Product Description

One. Equipment Introduction

1.1This equipment is based on UL 1642-2009And UL2054 standard design and manufacture, the main function is used to observe the battery after a series of changes in the flame heating and the size of the impact force generated by the explosion.

 

II. Brief Description of Principle

Due to the danger of the equipment combustion test, for protection, all operations of this test are required to be tested in a room separated from the observer!

For the flame exposure test, the test sample cell or battery is placed horizontally on the small steel wire mesh covered on the test base. Before the test, adjust the position of the burner so that the steel wire mesh is about 38.1mm above the burner.at. After adjusting the position, ignite the flame. After the steel wire mesh is red, use crucible tongs to hold the sample and place it on the net to burn until the battery explodes or burns!

When testing as burning particles, first remove the octagonal protective cover and top cover part above the equipment, place the test sample single cell or battery on the steel wire mesh covered on the test base, adjust the proportion of gas and air flow, make the burner produce bright blue flame, and make the steel wire mesh burn into bright red (about 700About degrees), according to the standard requirements to place the gauze screen (this equipment gauze screen equipment is not configured, by the test personnel to configure), has been burning until the battery explosion or until the burning due to lithium combustion!

When it is used as a projectile test, it is required to cover the sample with an octagonal protective cover and a top cover. The sample is placed on the steel wire mesh covered on the test base, and the sample is heated until the sample is exploded and burned due to lithium combustion!

 

III. Technical Indicators

12. Burner specification:ULBurners,Length100mm,Caliber38mm.The fuel used for the burner is propane gas!

2Flame height:10-75±2mm.

3.2Working conditions

Operating temperature range:0℃~40℃

Input power: AC220V/50HZ

Power consumption: ≤300W

Fuse:3A

3.3Safety index

Insulation resistance: shell, power input is greater than each other2MΩ

Withstand voltage: between power input and shell1Second withstand voltage1750V, setting current10mA

Grounding: power grounding electrode, the resistance between the shell is less0.1Ω

Online Inquiry

Submit