Lijia, New Energy Vehicle Industry Equipment Test Recommendation

Source:

Release date: 2021-09-10

As one of the environmental stress screening tests, the temperature shock test of the cold and heat shock box can directly affect the dynamic performance, endurance and safety of the car. The research and development test of the battery can promote the optimization iteration of the battery and achieve the high standard performance and safety management of the battery. Has a vital role.

Failure Phenomenon of Common Products Caused by Cold and Heat Shock

1. The extreme rise in temperature leads to the phenomenon of solder reflow;

2. When starting the motor, the temperature of the surrounding devices rises rapidly, and when the motor is closed, the temperature of the surrounding devices will drop suddenly;

3. The equipment is moved from the indoor with higher temperature to the outdoor with relatively lower temperature, or from the outdoor with relatively lower temperature to the indoor with higher temperature;

4. The device may be connected to the power supply in a low temperature environment, resulting in a steep temperature gradient inside the device.

Cutting off the power supply in a low temperature environment may cause a steep temperature gradient in the opposite direction inside the device;

5. The equipment may suddenly cool down due to rainfall;

6. When the aircraft takes off or lands, the external equipment on the aircraft may have a sharp change in temperature.

Both high and low temperature failures are reflected in the hot and cold temperature shock test, which only accelerates the generation of high and low temperature failures. Therefore, in order to maintain the reliability of the product, thermal shock test is essential.

Definition of hot and cold shock test

Thermal shock test (Thermal Shock Testing) is often called temperature shock test (Temperature Shock Testing) or temperature cycle (Temperature Cycling), high and low temperature cold and heat shock test.

   

According to the GJB 150.5A-2009 3.1, the temperature shock is a sharp change in the ambient air temperature of the equipment, and the temperature change rate is greater than 10 degrees/min, which is the temperature shock. MIL-STD-810F 503.4(2001) holds a similar view.

The purpose of the hot and cold shock test

In fact, the cold and hot shock test box as a tool for cold and hot shock test, the purpose of application in different stages of product development is different:

1. The engineering development stage can be used to find product design and process defects;

2. The product finalization or design appraisal and mass production stage are used to verify the adaptability of the product to the temperature shock environment, and provide the basis for the design finalization and mass production acceptance decision;

3. As an environmental stress screening application, the purpose is to eliminate the early failure of the product.

4. Confirm the changes in product characteristics in a short period of time, as well as the failure problems caused by the different thermal expansion coefficients of the different materials that make up the components. These changes can be observed by rapidly alternately exposing the component to ultra-high and ultra-low temperature test environments.

The difference between two-box type and three-box type cold and hot impact box

★LTR two-box cold and hot shock test chamber★

The test chamber generates a high temperature environment (40 ℃ ~ 200 ℃) and a low temperature environment (0 ℃ ~-80 ℃) respectively through the heating system and cooling system of the unit. According to the relevant requirements of the temperature shock test, the test article is put into the basket of the designated greenhouse. When the two greenhouses reach the preset temperature and are stable, the basket is pulled through the transmission mechanism, the movement of the measured element in the basket between the high and low temperature chambers is realized.

   

During the movement, the high and low temperature chambers are connected, and the measured element also enters another greenhouse from the high or low temperature state, so a large amount of cold and heat load will be brought in, and the unit will quickly return to the predetermined temperature of each greenhouse through the refrigeration system or heating system.

When the temperature of the greenhouse where the measured element is located remains stable for a long time, the load basket is reversely pulled through the transmission mechanism to bring the measured element back to the original greenhouse. The temperature must also be quickly restored to the predetermined temperature. When the temperature is stable for a long time again, the above operation is repeated to complete multiple temperature cycle impact tests.

★LTS three-box cold and hot shock test chamber★

Built-in pre-cooling zone, preheating zone and test zone, the three zones are independent respectively, the test product does not need to be moved by switching between the three boxes through the air door, when impacting the normal temperature, the ambient temperature is introduced into the test space through the air blower, the heat or cold quantity of the test space is eliminated, and the air door of the high and low temperature tank is closed at the same time;

When the low temperature is impacted, the high temperature and normal temperature tank air doors are closed, the low temperature tank is connected with the test box, and the pre-stored cold quantity is introduced into the test box instantly;

When the high temperature is impacted, the low temperature and normal temperature tank air doors are closed, and the high temperature tank is connected with the test box, and the pre-stored heat is instantly introduced into the test box. So as to achieve the purpose of rapid alternating temperature.

Procedure for Hot and Cold Shock Test

The cold and hot shock test box has certain specifications during use. Users also need to understand the operation process of the cold and hot shock test box when using it. Let's take a look at the specific operation process.

In general, the test Nc is a cold and hot shock test, and the temperature change is completed by a liquid medium.

The test samples were tested in an unpackaged state.

Test cycle: Immerse the test sample at the ambient temperature of the laboratory in a low-temperature liquid tank at the temperature TA specified in the relevant specifications for the specified time t1.

Take out the test sample from the low-temperature liquid tank within the specified conversion time t2 and immerse it in the high-temperature liquid tank. The temperature of the liquid in the tank is the temperature TB specified in the relevant specifications, and keep it for the specified time t2.

Remove the test sample from the high temperature liquid tank. The conversion time t2 when the test sample is taken out of the high-temperature liquid tank and immersed in the low-temperature liquid tank shall meet the requirements of relevant specifications.

A cycle includes 2 immersion times t1 and 2 conversion times t2, as shown in the figure below.

At the end of the last cycle, the test specimen shall be subjected to a recovery procedure. The test sample shall be kept under the test standard atmospheric conditions long enough to achieve temperature stability.

Finally, the test samples were detected.

Today, the new energy power battery industry is still rapidly iteratively updated. Guangdong Lijia also closely combines the research and development project of testing technology machine with the new energy industry to actively provide solid power support for the development of the new energy automobile industry.