[High and Low Temperature Test Chamber] How to Solve Surface Frosting
Source:
Release date: 2019-05-02
The high and low temperature test chamber is suitable for the reliability test of industrial products at high temperature and low temperature. The parts and materials of electronic and electrical, automobile and motorcycle, aerospace, marine weapons, colleges and universities, scientific research institutions and other related products are tested for their various performance indicators under the condition of cyclic changes of high temperature and low temperature (alternating).
On the high and low temperature test chamber compressor shell frosting problem, in the final analysis is the maintenance of the problem, the quality of the equipment itself is on the one hand, but the equipment maintenance of the service life of the equipment also played an important role.
1.After the art tube of the high and low temperature test chamber is opened, it is not sealed or repaired in time. Long-term shelving frost and frequent startup will bring moisture in the air from the outside of the pipe into the machine.;There are also unsealed compressors that have been placed for a long time. If they are used without drying, they will be replaced by frost, which will also cause icing.
2.After the refrigeration evaporator is damaged, it will be frozen after being turned on for a long time.(Tibetan)The water molecules in the chamber are brought into the compressor together with the water vapor in the air.(When the generator is turned on, negative pressure is generated in the generator, and the atmospheric pressure brings the water molecules in the humid air into the machine.).
3.If the evaporator of the high and low temperature test chamber is poorly ventilated and the cold capacity cannot be taken away, the evaporator will be frosted or frozen, resulting in low pressure and low pressure, which will also cause frost on the compressor shell.
4.Under normal working conditions of the high and low temperature test chamber, the compressor sucks back refrigerant vapor instead of liquid. If there is too much refrigerant in the refrigeration system and too much refrigerant oil is charged or the expansion valve adjustment flow rate is too large, the refrigerant is not completely caifa in the evaporator, causing the refrigerant to be sucked back by the compressor in wet vapor or liquid state, and charging will cause freezing.
5.The compressor of the high and low temperature test chamber compresses the water vapor in the air into water during pressurized leakage, which is injected into the pipeline, thus causing junction.Ice.
The above explanation hopes that everyone can understand the problem of surface finish on the operation and maintenance of high and low temperature test chambers.