Lijia Quality Recommendation: [Constant Temperature and Humidity Test Chamber] Professional Environmental Test Equipment

Source:

Release date: 2019-05-25

Constant temperature and humidity test chamberAlso calledConstant temperature and humidity testing machine,Constant temperature and humidity experiment box,Constant temperature machineorConstant temperature and humidity boxEquipment for testing the performance of materials in various environments and testing the heat resistance, cold resistance, dry resistance and humidity resistance of various materials. Suitable for electronics, electrical appliances, communications, instrumentation, vehicles, plastic products, metals, food, chemistry, building materials, medical, aerospace, etc.industry,In the hot and humid environment, test its performance indicators.

Compliance with standards:GB/T5170.5-2008,GB/T10586-2006,GB/T2423.1-2008TestA,GB/T2423.2-2008TestB,GB/T2423.3-2006TestCa,GB/T2423.4-2008TestDb。

Technical parameters

1Temperature range:-60℃ ~150℃

2Humidity range:30~98%RH(temperature25℃ ~80℃)

3Uniformity of temperature:≤2℃ (no-load)

4Humidity Uniformity: 2,-3%RH

5Temperature fluctuation:±0.5℃ (no-load)

6Humidity fluctuation:±2%

72. Temperature deviation:±2℃

8Humidity deviation:±2%

92. Cooling rate:0.7~1.0℃/min

10Heating speed:1.0~3.0℃/min

11Time setting range:1~9999H

12Humidity alternating range:40~98%RH

 

 

Equipment structure

The inner container of the box is made of imported high-grade stainless steel (SUS304) Mirror panel or304BMade by argon arc welding, the outer tank of the box adoptsA3Plastic-sprayed steel plate;

Using microcomputer temperature and humidity controller, temperature and humidity control is accurate and reliable;

The large observation window is attached with lighting lamp to keep the box bright, and double glazing is used to clearly observe the situation in the box at any time;

An independent temperature limit alarm system is provided, which automatically interrupts when the temperature exceeds the limit to ensure the safe operation of the experiment without accidents;

Left side of box with diameter50mmThe test hole.

Classification difference

1. Test type: humidity in20-98%The temperature is usually high150degree, the low temperature part is divided0degree,-20degree,-40degree,-60degrees and other unequal specifications.

2. Culture biochemical type: the temperature range is usually0-50Between degrees, humidity in50-95Between.This is suitable for food bacterial culture and other industries.

Use of the environment

Allowable working environment:0~35℃ performance guarantee environment:5~25C.

The installation ground is required to be level ground.

3. Distance around the test chamber600MM.